Post Offer Free
Ningbo Gelante Electric Co., Ltd.
Ningbo Gelante Electric Co., Ltd.  

Gold Index: 3956

You are here: home  > PDU Sockets  > Standard PDU  > universal type power distribution unit

universal type power distribution unit 

Price: 7.0~10.0 USD 
Payment Terms: T/T,L/C 
Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Means of Transport: Ocean
Packing: 1PCS/box
Brand Name: HUIPAI
Production Capacity: 500PCS/DAY
Delivery Date: 30day

6-20 outlets
Double-break Switch
Overload Protector
Breaker(Air switch)
SPD Surg excluder
OEM for all the type and different length

Product name:Power Distribution Unit
6-20 outlets  
Double-break Switch
Overload Protector
Breaker(Air switch)
SPD Surg excluder
OEM for all the type and different length


--------Power Distribution Unit
A power distribution unit (commonly abbreviated to PDU) is a device that distributes electric power.
There tends to be two major types: Heavy Floor Mounted PDU devices which take main feeds and distribute into a handful of smaller feeds. Facilities professionals will refer to these as PDUs as well, but these are only floor mounted. The second type of PDU is the rack-based PDU. Sometime called Smart-PDU, PDU, or Power Strip by IT professionals.
Rack-Based PDU units are used for taking high voltage and current and reducing it to more common and useful levels, for example from 240V 30A single phase to multiple 120V 15A or 120V 20A plugs. They are used in computer data centers, stage shows, by DJs, and in other electrically intensive applications. Some premium units have features like remote power monitoring and power state control down to the unit or individual plug level. Certain manufactures also include environmental monitoring via RS485, USB, Dallas 1-Wire or Serial ports. The power outlets themselves are typically IEC-C19, IEC-C13 or NEMA 5-20 style outlets.
Rack-based PDU refers to what amounts to a well-constructed power strip suitable for data center use. Two basic varieties distinguished by the type of input power are common: single-phase and three-phase. The output power (i.e. the power to the load device) is almost always single-phase, however. In the case of a three-phase PDU, each of the three phases appears individually on one-third of the included receptacles. Rack-PDUs can be dumb—meaning that they have no instrumentation and are not manageable, or they can be metered—meaning that they are equipped with a display that shows current load on each phase, or they can be switched and metered meaning that some or all of their receptacles can be individually switched on or off remotely and the meter usage as well.
bigPhoto
 Ms. candice yu

Tel: 86-574-63661713
Fax: 86-574-63661781
Mobile: 139 6824 5805
Contact to this supplier

Didn't find what you're looking for? Post Buying Lead or contact HiSupplier Customer Service Center  for help!

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Ningbo Gelante Electric Co., Ltd. [China (Mainland)]


Business Type:Manufacturer, Trading Company
City: Ningbo
Province/State: Zhejiang
Country/Region: China (Mainland)

You May Like: